Research Article

FREE SET POINT TRACKING AND DISTURBANCE REJECTION OF BINARY DISTILLATION COLUMN USING MODEL PREDICTIVE CONTROL

1 Department of Electrical and Electronic Engineering, University of Jos, Nigeria.
2 Department of Computer Engineering, Ahmadu Bello University, Nigeria.
3 University of Jos: Electrical & Electronic Engineering department, Jos – Nigeria
4 Department of Mechanical Engineering, Ahmadu Bello University, Zaria
5 Department of Electrical and Electronic Engineering, University of Jos, Nigeria
* Corresponding author: tasalawudeen@abu.edu.ng
Published: Sep, 2019
Pages: 50-55
Views: 57
Downloads: 16

Abstract

Off set free set point tracking is a challenging problem in distillation column control. This isusually due to the multivariable nature of the distillation column and hence the interactionbetween the loops. This study designed a model predictive controller using MATLAB andSimulink for a Lubyen Vinate Distillation Column. The results show that the model predictivecontroller performs an off set free set point tracking and disturbance rejection of about 70%.The system has a fast settling time of 5 minutes and 3 minutes for the 17th and 4th columnrespectively. This shows that the designed system has an efficient control as compared to theresponse of distillation column 60 minutes and 40 minutes for the 17th and 4th columnrespectively.

References

  1. D. E. Seborg, D. A. Mellichamp, T. F. Edgar, and F. J. Doyle III, Process dynamics and control. John Wiley & Sons, 2010.
  2. M. Senthilkumar, A. J. I. J. o. E. R. Lincon, and Development, "Design of stabilizing PI controller for coupled tank MIMO process," vol. 3, no. 10, pp. 47-55, 2012.
  3. M. Hamdy, A. Ramadan, and B. J. J. o. I. M. Abozalam, "A novel inverted fuzzy decoupling scheme for MIMO systems with disturbance: a case study of binary distillation column," vol. 29, no. 8, pp. 1859-1871, 2018.
  4. C. Rajapandiyan, M. J. I. Chidambaram, and E. C. Research, "Controller design for MIMO processes based on simple decoupled equivalent transfer functions and simplified decoupler," vol. 51, no. 38, pp. 12398-12410, 2012.
  5. M. Noeding, J. Martensen, N. Lemke, W. Tegethoff, and J. Koehler, "Selection of Decoupling Control Methods Suited for Automated Design for Uncertain TITO Processes," in 2018 IEEE 14th International Conference on Control and Automation (ICCA), 2018, pp. 498-505: IEEE.
  6. F. G. Shinskey, Process control systems. McGraw-Hill, Inc, 1979.
  7. W. L. J. I. Luyben, E. C. P. Design, and Development, "Simple method for tuning SISO controllers in multivariable systems," vol. 25, no. 3, pp. 654-660, 1986.
  8. B. W. Bequette, Process control: modeling, design, and simulation. Prentice Hall Professional, 2003.
  9. Q.-G. Wang, B. Zou, T.-H. Lee, and Q. J. A. Bi, "Auto-tuning of multivariable PID controllers from decentralized relay feedback," vol. 33, no. 3, pp. 319-330, 1997.
  10. Q.-G. Wang, B. Huang, and X. J. I. t. Guo, "Auto-tuning of TITO decoupling controllers from step tests," vol. 39, no. 4, pp. 407-418, 2000.
  11. Z. Hu, D. Li, J. Wang, and F. J. J. Xue, "Analytical Design of PID Decoupling Control for TITO Processes with Time Delays," vol. 6, no. 6, pp. 1064-1070, 2011.
  12. J. G. Ziegler and N. B. J. t. A. Nichols, "Optimum settings for automatic controllers," vol. 64, no. 11, 1942.
  13. P. Bagheri, B. Ali, A. K. Sedigh, J. K. J. I. C. T. Sedigh, and Applications, "Analytical approach to tuning of model predictive control for first-order plus dead time models," vol. 7, no. 14, pp. 1806-1817, 2013.
  14. D. E. Rivera, M. Morari, S. J. I. Skogestad, e. c. p. design, and development, "Internal model control: PID controller design," vol. 25, no. 1, pp. 252-265, 1986.
  15. L. Rose, "Comparitive study of various level control techniques for a two tank system," in 2015 International Conference on Innovations in Information, Embedded and Communication Systems (ICIIECS), 2015, pp. 1-4: IEEE.
  16. R. Kumar, S. Singla, V. J. J. o. a. r. Chopra, and technology, "Comparison among some well known control schemes with different tuning methods," vol. 13, no. 3, pp. 409-4015, 2015.
  17. C. E. Garcia, M. J. I. Morari, E. C. P. Design, and Development, "Internal model control. A unifying review and some new results," vol. 21, no. 2, pp. 308-323, 1982.
  18. C. E. Garcia, D. M. Prett, and M. J. A. Morari, "Model predictive control: theory and practice—a survey," vol. 25, no. 3, pp. 335-348, 1989.
  19. G. Shah and S. Engell, "Tuning MPC for desired closed-loop performance for MIMO systems," in Proceedings of the 2011 American Control Conference, 2011, pp. 4404-4409: IEEE.
  20. J. Flores-Cerrillo and J. F. J. J. o. p. c. MacGregor, "Latent variable MPC for trajectory tracking in batch processes," vol. 15, no. 6, pp. 651-663, 2005.
How to Cite

Salawudeen, A. T., Haruna, Z., Yahaya, B., Egbujo, I. F., Bello, U. R., Zubairu, A. Y., Nwokocha, I., & Hamisu, I. (2019). FREE SET POINT TRACKING AND DISTURBANCE REJECTION OF BINARY DISTILLATION COLUMN USING MODEL PREDICTIVE CONTROL. Zaria Journal of Electrical Engineering Technology, 8(2), 50-55. https://doi.org/10.67203/zjeet.2019.y7fenwes

A. T. Salawudeen, Z. Haruna, B. Yahaya, I. F. Egbujo, U. R. Bello, A. Y. Zubairu, I. Nwokocha, and I. Hamisu, "FREE SET POINT TRACKING AND DISTURBANCE REJECTION OF BINARY DISTILLATION COLUMN USING MODEL PREDICTIVE CONTROL," Zaria Journal of Electrical Engineering Technology, vol. 8, no. 2, pp. 50-55, September 2019. doi: 10.67203/zjeet.2019.y7fenwes

Share this article: