Research Article Vol. 14, Issue 1

Optimized PID Based Load Frequency Control of a Hybrid Microgrid

S. M. Aminu*, Y. Jibril, A. Abdulkarim, A.S. Abubakar

This research presents the development of an optimized PID based load frequency control of a hybrid microgrid. The micro-grid (MG) concept allows the renewable energy sources to operate in both synchronized grid and islanded/stand-alone mode. These modes of operations of the MG have made it smart, hence require intelligent coordinated control strat...

2
Research Article Vol. 14, Issue 1

Development of Load Frequency Control of Two Area Interconnected Network Incorporated with Distributed Energy Sources

Adamu, Ahmed Kana*, A. B. Kunya, A.S. Abubakar

The frequency of power systems is highly sensitive to load changes, and the increasing integration of distributed energy sources (DESs) further complicates frequency stabilization. To address these challenges, Load Frequency Control (LFC) is implemented to maintain frequency within acceptable limits. This work proposes a grasshopper optimization al...

3
Research Article Vol. 13, Issue 1

Load Frequency Control of a Two Area Network using Fractional PID Controller

This paper simulates load frequency control (LFC) problem in a two-area power system using a traditional PID controller and a Fractional Proportional-Integral-Derivative (FPID) controller. The study aims to enhance the stability and performance of the power system by minimizing frequency deviations and maintaining the desired power exchange between...

4
Research Article Vol. 13, Issue 1

Design of Static Var Compensator for Voltage Stability Improvement in 30 bus network

A. Markus*, A.S. Abubakar, I. Seidu, Zaharadeen Musa

This paper presents a comprehensive study on the application of Static Var Compensator (SVC) devices for voltage stability and load flow optimization in the IEEE 30-bus power system. As modern power networks face increasing demand and complexity, maintaining voltage levels and minimizing power losses are critical challenges. This research investiga...

5
Research Article Vol. 13, Issue 1

Optimal Scheduling Scheme of an Autonomous Microgrid Considering the Operational and Maintenance Costs of the Micro-Sources

Abubakar Ahmed*, A.S. Abubakar, A. B. Kunya

The solution of the combined Economic-Emission Load Dispatch (EELD) problem of conventional or micro-grid (MG) system entails determination of the optimal power output of dispatchable generating units, to meet the system load, at the lowest possible cost and reduced greenhouse gases emission, subject to some constraints. In most studies, the instal...

6
Research Article Vol. 13, Issue 1

Development of Optimized Maximum PowerPoint Tracking Scheme for A Partially Shaded Photovoltaic System

M. Aderinola*, A.S. Abubakar, A. B. Kunya

Solar energy harnessed through photovoltaic (PV) technology plays a pivotal role in generating electrical energy. Maximizing the power output of solar modules requires optimal solar radiation. However challenges arise due to obstacles such as stationary objects, building, tree leaves and winds, which can result in the presence of multiple points of...

7
Research Article Vol. 12, Issue 1

Voltage stability enhancement Scheme using PV-reinforced Dynamic Voltage Restorer

J. A. Joseph*, G. A. Olarinoye, A.S. Abubakar

Among the promising solutions proposed for the mitigation of the voltage instabilities is a series compensator known as Dynamic Voltage Restorers (DVR) due to its flexibility and cost effectiveness. Dynamic Voltage Restorer (DVR) also known as Static Synchronous Series Compensator (SSSC) is a series compensation technique used in the distribution a...

8
Research Article Vol. 12, Issue 1

Reconfiguration of Unbalanced Distribution Network for Improved Voltage Profile and Power Loss Mitigation

The need for improved quality of services, and an increase in energy demand among others necessitated the urgent need for efficient utilization of the available energy via reducing technical losses in the network. This paper proposed a power loss mitigation scheme by developing an optimal reconfiguration for an unbalanced Distribution Network (DN) ...

9
Research Article Vol. 12, Issue 1

Pitch Angle Control for a Permanent Magnet Synchronous Generator-based Wind Energy System based on Proportional Resonant (PR)

F. Hassan*, A.S. Abubakar

The study presents the development of a Proportional-resonant (PR) based pitch angle control strategy for a 2MW Permanent magnet synchronous generator (PMSG) based wind energy system. The model in this work comprises of wind turbine, Permanent Magnet Synchronous Generator (PMSG), AC-DC converter, DC-DC boost converter and Pitch angle of a standard ...

10
Research Article Vol. 12, Issue 1

Development of Improved Particle Swarm Optimization Algorithm Based on Success Rate for Optimal Placement of DG on Distribution Network

H. Yusuf*, A.S. Abubakar, Y. Jibril, J. Abubakar

The increase in load demand of distribution networks, made the role of distribution systems (DSs) difficult for the power utilities. However, thoughtful planning for supplementary power reimbursement are necessary on DSs for power loss and voltage deviation minimization which is done by optimization techniques. An Improved Particle Swarm Optimizati...